Industrial Recycling Solutions Inc
NON-CHLORINATED BRAKE CLEANER MSDS
SECTION I
Chemical
Product and Company Identification
Product
Trade Name: Desert Breeze NCBC
Product
Name: NON-CHLORINATED BRAKE CLEANER
Chemical
Family: Petroleum Hydrocarbon
General
identification or generic identification: C6 ALIPHATIC ISOMERS
MSDS
# 10010
Manufactured
and Distributed by: Phone:
602-268-4022 Fax: 623-979-9058
Industrial Recycling
Solutions
2610 West Holly Street #C Emergency phone: Chemtrec 800-424-9300
Phoenix, AZ
85009-2600
Mailing
Address: P O Box 878, Peoria,
AZ 85380-0878
SECTION II
THE
COMPOSITION OF THIS MIXTURE MAY BE PROPRIETARY INFORMATION. IN THE EVENT OF A MEDICAL EMERGENCY,
COMPOSITIONAL INFORMATION WILL BE PROVIDED TO A PHYSICIAN OR NURSE.
THIS
PRODUCT IS HAZARDOUS AS DEFINED IN 29 CFR1910.1200, BASED ON THE FOLLOWING
COMPOSITIONAL INFORMATION:
OSHA HAZARD COMPONENT
FLAMMABLE PETROLEUM
HYDROCARBONS
OSHA PEL; ACGIH TLV HEXANE,
CYCLOHEXANE
CNS EFFECTS HEXANE
Section III
POTENTIAL
HEALTH EFFECTS
EYE
CONTACT:
SLIGHTLY IRRITATING BUT DOES NOT
INJURE EYE TISSUE.
SKIN
CONTACT:
FREQUENT OR PROLONGED CONTACT MAY
IRRITATE AND CAUSE DERMATITIS.
INHALATION:
HIGH VAPOR/AEROSOL CONCENTRATIONS (GREATER THAN
APPROXIMATELY 1000 PPM) ARE IRRITATING TO THE EYES AND THE RESPIRATORY TRACT,
MAY CAUSE HEADACHES, DIZZINESS, ANESTHESIA, DROWSINESS, UNCONSCIOUSNESS, AND
OTHER CENTRAL NERVOUS SYSTEM EFFECTS, INCLUDING DEATH.
MAY CAUSE PERIPHERAL NERVOUS SYSTEM DISORDER
AND / OR DAMAGE.
INGESTION:
SMALL AMOUNTS OF THIS PRODUCT ASPIRATED INTO THE
RESPIRATORY SYSTEM DURING INGESTION OR VOMITING MAY CAUSE MILD TO SEVERE
PULMONARY INJURY, POSSIBLY PROGESSING TO DEATH.
LOW ORDER OF TOXICITY.
CHRONIC
EFFECTS:
OVEREXPOSURE TO THIS PRODUCT MAY CAUSE PROGRESSIVE
AND POTENTIALLY IRREVERSIBLE DAMAGE TO THE PERIPHERAL NERVOUS SYSTEM,
PARTICULARLY IN THE ARMS AND LEGS.
Section 1V
EYE
CONTACT:
FLUSH EYES WITH LARGE AMOUNTS OF WATER UNTIL
IRRITATION SUBSIDES. IF IRRITATION
PERSISTS, GET MEDICAL ATTENTION.
SKIN
CONTACT:
FLUSH WITH LARGE AMOUNTS OF WATER,
USE SOAP IF AVAILABLE.
REMOVE GROSSLY CONTAMINATED CLOTHING, INCLUDING
SHOES, AND LAUNDER BEFORE REUSE.
INHALATION:
USING PROPER RESPIRATORY PROTECTION, IMMEDIATELY
REMOVE THE AFFECTED VICTIM FROM EXPOSURE.
ADMINISTER ARTIFICIAL RESPIRATION IF BREATHING IS STOPPED. KEEP AT REST.
CALL FOR PROMPT MEDICAL ATTENTION.
INGESTION:
IF SWALLOWED, DO NOT INDUCE VOMITING. KEEP AT REST.
GET PROMPT MEDICAL ATTENTION.
Section V
FLASH
POINT <
0 DEG F.
FLAMMABLE
LIMITS: LEL:
1.8 UEL: 11.6@77 DEG F.
NOTE:
APPROXIMATE AUTOIGNITION TEMPERATURE: 511 DEG F.
GENERAL
HAZARD:
EXTREMELY FLAMMABLE, LATERIAL WILL READILY IGNITE AT
AMBIENT TEMPERATURES. TOXIC GASES WILL
FORM UPON COMBUSTION. STATIC DISCHARGE,
MATERIAL CAN ACCUMULATE STATIC CHARGES WHICH CAN CAUSE AN INCENDIARY ELECTRICAL
DISCHARGE. .EMPTY. CONTAINERS RETAIN
PRODUCT RESIDUE (LIQUID AND/OR VAPOR) AND CAN BE DANGEROUS. DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER,
DRILL, GRIND, OR EXPOSE SUCH CONTAINERS TO HEAT, FLAME, SPARKS, STATIC
ELECTRICITY, OR OTHER SOURCES OF IGNITION; THEY MAY EXPLODE AND CAUSE INJURY OR
DEATH. EMPTY DRUMS SHOULD BE COMPLETELY
DRAINED, PROPERLY BUNGED AND PROMPTLY RETURNED TO A DRUM RECONDITIONER, OR
PROPERLY DISPOSED OF.
FIRE-FIGHTING
USE WATER SPRAY TO COOL FIRE EXPOSED SURFACES AND TO
PROTECT PRESONNEL. SHUT OFF .FUEL. TO
FIRE. IF A LEAK OR SPILL HAS NOT IGNITED,
USE WATER SPRAY TO DISPERSE THE VAPORS.
EATHER ALLOW THE FIRE TO BURN UNDER CONTROLLED
CONDITIONS OR EXTINGUISE WITH FOAM OR DRY CHEMICAL. TRY TO COVER LIQUID SPILLS WITH FOAM. RESPIRATORY AND EYE PROTECTION REQUIRED FOR
FIRE FIGHTING PERSONNEL. THIS LIQUID IS
VOLATILE AND GIVES OFF INVISIBLE VAPORS.
EITHER THE LIQUID OR VAPOR MAY SETTLE IN LOW AREAS OR TRAVEL SOME
DISTANCE ALONG THE GROUND OR SURFACE TO IGNITION SOURCES WHERE THEY MAY IGNITE
OR EXPLODE.
DECOMPOSITION PRODUCTS UNDER
FIRE CONDITIONS
Section VI
Accidental release
measures
ELIMINATE SOURCES OF IGNITION. PREVENT ADDITIONAL DISCHARGE OF MATERIAL; IF
POSSIBLE TO DO SO WITHOUT HAZARD. FOR
SMALL SPILLS IMPLEMENT CLEANUP PROCEDURES; FOR LARGE SPILLS IMPLEMENT CLEANUP
PROCEDURES AND, IF IN PUBLIC AREA, KEEP PUBLIC AWAY AND ADVISE
AUTHORITIES. ALSO, IF THIS PRODUCT IS
SUBJECT TO CERCLA REPORTING (SEE SECTION 15 REGULATORY INFORMATION) NOTIFY THE NATIONAL RESPONE CENTER. PREVENT LIQUID FROM ENTERING SEWERS,
WATERCOURSES, OR LOW AREAS. CONTAIN
SPILLED LIQUID WITH SAND OR EARTH. DO
NOT USE COMBUSTIBLE MATERIALS SUCH AS SAWDUST.
RECOVER BY PUMPING (USE AN EXPLOSION PROOF OR HAND
PUMP) OR WITH A SUITABLE ABSORBENT.
CONSULT AN EXPERT ON DISPOSAL OF RECOVERED MATERIAL
AND ENSURE CONFORMITY TO LOCAL DISPOSAL REGULATIONS.
WATER
SPILL
ELIMINATE SOURCES OF IGNITION. WARN OCCUPANTS AND SHIPPING SUROUNDING AND
DOWNWIND AREAS OF FIRE AND EXPLOSION HAZARD AND REQUEST ALL TO STAY CLEAR.
CONSULT AN EXPERT ON DISPOSAL OF RECOVERED MATERIAL
AND ENSURE CONFORMITY TO LOACAL DISPOSAL REGULATIONS.
Section VII
ELECTROSTATIC
ACCUMULATION HAZARD:
YES, USE PROPER BONDING AND/OR GROUNDING PROCEDURE.
ADDITIONAL INFORMATION REGARDING SAFE HANDLING OF
PRODUCTS WITH STATIC ACCUMULATION POTENTIAL CAN BE ORDERED BY CONTACTING THE
AMERICAN PETROLEUM INSTITUTE (API) FOR API RECOMMENDED PRACTICE 2003, ENTITLED
.PROTECTION AGAINST IGNITIONS ARISING OUT OF STATIC, LIGHTING, AND STRAY
CURRENTS. (AMERICAN PETROLEUM INSTITUTE, 1220 L STEET NORTHWEST, WASHINGTON, DC
20005), OR THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) FOR NFPA 77 ENTITLED
.STATIC ELECTRICITY. (NATIONAL FIRE PROTECTION ASSOCIATION, 1 BATTERYMARCH
PARK, P.O. BOX 9101, QUINCY, MA 02269-9101
STORAGE
TEMPERATURE, DEF F:
AMBIENT
LOADING/UNLOADING
TEMPERATURE, DEG F:
AMBIENT
STORAGE/TRANSORT
PRESSURE, MMHG:
ATMOSPHERIC
LOADING/UNLOADING
VISCOSITY, CST:
1
STORAGE
AND HANDLING:
KEEP CONTAINER CLOSED. HANDLE AND OPEN CONTAINERS WITH CARE. STORE IN A COOL, WELL-VENTILATED PLACE AWAY
FROM INCOMPATIBLE MATERIALS. DO NOT
HANDLE OR STORE NEAR AN OPEN FLAME, HEAT OR OTHER SOURCES OF IGNITION. PROTECT MATERIAL FROM DIRECT SUNLIGHT. MATERIAL WILL ACCUMULATE STATIC CHARGES WHICH
MAY CAUSE AN ELECTRICAL SPARK (IGNITION SOURCE). USE PROPER BONDING AND/OR GROUNDING
PROCEDURES. DO NOT PRESURIZE, CUT, HEAT,
OR WELD CONTAINERS. EMPTY PRODUCT
CONTAINERS MAY CONTAIN PRODUCT RESIDUE.
DO NOT REUSE EMPTY CPNTAINEWRS WITHOUT COMMERCIAL CLEANING OR
RECONDITIONING.
Section VIII
Exposure
controls/personal protection
EXPOSURE
CONTROLS:
THE USE OF LOCAL EXHAUST VENTILATION IS RECOMMENDED
TO CONTROAL PROCESS EMMISSIONS NEAR THE SOURCE.
LABORATORY SAMPLES SHOULD BE HANDLED IN A LAB HOOD. PROVIDE MECHANICAL VENTILATION OF CONFINED
SPACES. SEE RESPIRATORY PROTECTION
RECOMMENDATIONS. USE EXPLOSION-PROOF
VENTILATION EQUIPMENT.
PERSONAL
PROTECTION
FOR OPEN SYSTEMS WHERE CONTACT IS LIKELY, WEAR
SAFETY GLASSES WITH SIDE SHIELDS, LONG SLEEVES, AND CHEMICAL RESISTANT
GLOVES. WHERE CONTACT MAY OCCUR, WEAR SAFETY
GLASSES WITH SIDE SHIELDS. WHERE
CONCENTRATIONS IN AIR MAY EXCEED THE LIMITS GIVEN IN THIS SECTION AND
ENGINEERING, WORK PRACTICE OR OTHER MEANS OF EXPOSURE REDUCTION ARE NOT
ADEQUATE, NIOSH/MSHA APPROVED RESPIRATORS MAY BE NECESSARY TO PREVENT OVEREXPOSURE
BY INHALATION.
WORKPLACE
EXPOSURE GUIDELINES
OSHA REGULATION 29CFR1010.1000 REQUIRES THE
FOLLOWING PERMISSIBLE EXPOSURE LIMITS:
A TWA OF 50 PPM
VENDER
RECOMMENDS THE FOLLOWING LIMITS
A
TWA OF 50 PPM BASED ON TOTAL HYDROCARBON.
Section IX
PHYSICAL
AND CHEMICAL PROPERTIES
SPECIFIC
GRAVITY, AT DEG F: 0.68
AT 60
VAPOR
PRESSURE, MMHG AT DEG F: 150
AT 68
SOLUBILITY
IN ATER, WT. % AT DEG F: LESS
THAN 0.01 AT 77
VISCOSITY
OF LIQUID, CST AT DEG F: 0.5
AT 77 APPROXIMATE
SP.
GRAV. OF VAPOR, AT 1 ATM (AIR=1): 3.00
CALCULATED
FREEZING/
MELTING POINT, DEG F: LESS
THAN .76
EVAPORATION
RATE, N-BU ACETATE=1: 15.5
APPROXIMATE
BOILING
POINT, DEG F: 151
TO 160 APPROXIMATE
Section X
Stability and
Reactivity
STABILITY
STABLE
CONTITIONS TO AVOID INSTABILITY:
NOT APPLICABLE
HAZARDOUS POLYMERIZATION:
WILL NOT OCCUR
CONDITIONS TO AVOID
HAZARDOUS POLYMERIZATION:
NOT APPLICABLE
MATERIALS AND CONDITIONS TO
AVOID INCOMPATIBILITY:
HAZARDOUS DECOMPOSITION
PRODUCTS:
NONE
Section XI
DEPARTMENT OF TRANSPORTATION (DOT):
DOT SHIPPING DESCRIPTION: HEXANES,
3, UN 1208, 11
HAZARD
RATING SYSTEMS:
THIS INFORMATION IS FOR PEOPLE
TRAINED IN:
NATIONAL PAINT AND COATING
ASSOCIATION.S (NPCA)
HAZARDOUS MATERIALS IDENTIFICATION
SYSTEM (HMIS)
NATION FIRE PROTECTION ASSOCIATION
(NFPA 704)
IDENTIFICATION OF THE FIRE HAZARDS OF MATERIALS
NPCA-HMIS NFPA 704 KEY
HEALTH 1 1 4=SEVERE
FLAMMABILITY 3 3 3=SERIOUS
REACTIVITY 0 0 2=MODERATE
1=SLIGHT
ALL INFORMATION APPEARING HEREIN IS
BASED UPON DATA OBTAINED FROM THE MANUFACTURER AND/OR RECOGNIZED TECHNICAL
SOURCE. WHILE THE INFORMATION IS
BELIEVED TO BE ACCURATE, IRS MAKES NO REPRESENTATIONS AS TO ITS ACCURACY OR
SUFFICIENCY. CONDITIONS OF USE ARE
BEYOND IRS CONTROL AND THEREFORE USERS ARE RESPONSIBLE TO VERIFY THIS DATA
UNDER THEIR OWN OPERATING CONDITIONS TO DETERMINE WHETHER THE PRODUCT IS
SUITABLE FOR THEIR PARTICULAR PURPOSE AND THEY ASSUME ALL RISKS OF THEIR USE,
HANDLING, AND DISPOSAL OF THE PRODUCT, OR FROM THE PUBLICATION OR USE OF, OR
RELIANCE UPON, INFORMATION CONTAINED HEREIN.
|